695 Views
Share
Access anytime
108 Min
This course format through pre-recorded video. You can buy and watch it to learn at any time.
Mastering "HVAC Manual Cooling Load Calculation with Practical Example, Design Ideas, Issues & Questions" accelerates career growth for HVAC engineers, designers, and technicians. Professionals can transition into senior roles like HVAC Design Engineer, Building Services Manager, or Energy Efficiency Specialist, or specialize in HVAC system design, energy auditing, and building performance optimization. Expertise in manual cooling load calculation enhances job prospects, earning potential, and leadership opportunities, ensuring accurate and efficient HVAC system design, energy savings, and compliance with industry standards and building codes. This comprehensive knowledge enables professionals to drive innovation and excellence in building services and energy management.
HVAC Cooling Load Calculation
Basics of Psychrometry
Design issues related to Cooling Load Calculation
In HVAC Manual Cooling Load Calculation Videos (Part-1 to 6), all important basic parameters explanation of HVAC with formulas will be explained including the basic psychrometric parameters like Dry Bulb, Wet Bulb, Relative Humidity, Humidity Ratio with detailed examples for clear and easy understanding.
Also, it provides the details of how to find out the building thermal condition or weather properties from ASHRAE climatic condition, how to select indoor design condition, thermal zoning concept which includes the selection of thermostat, VAV (Variable Air Volume), CAV (Constant Air Volume).
Additionally, you can find out the concept of Sensible & latent load with formulas. A detailed explanation with formulas given to find out the Room Internal Sensible Load, Room External Sensible Load, External to Internal Sensible Load due to un-treated air, Latent Load.
It covers the details of how to find out the Fresh Air value for the room, concept of Fresh Air Handling Unit, U-Value, R-Value concepts and how to find out the U-Value of External Wall, Roof, Floor, Partition, Glass or Window with Carrier Handbook reference.
Sensible Heat Gain, Latent Heat gain, HVAC ducts leakage, FCU or DX Split units or other internal HVAC ducts concepts added to find out the sensible and latent safety factor.
At the end of the video, you will get to know how to find out the Ton of Refrigeration or KW of HVAC units along with the concept of How to find out the Air flow for HVAC units, How to find out the ON-COIL and OFF-COIL Temperature for HVAC units and how the HVAC cooling load software HAP is working and how to compare the results of HAP With manual cooling load calculation.
Industry domains :
Engineering Disciplines :
1
Part-1-HVAC Manual Cooling Load Calculation :
Part 1-HVAC Manual Cooling Load Calculation with Practical Example, Design Ideas, Issues & Questions
2
Part-2-HVAC Manual Cooling Load Calculation :
Part 2-HVAC Manual Cooling Load Calculation with Practical Example, Design Ideas, Issues & Questions
3
Part-3-HVAC Manual Cooling Load Calculation :
Part 3-HVAC Manual Cooling Load Calculation with Practical Example, Design Ideas, Issues & Questions
MD & CEO, SAURYAJYOTI REN...
Engineer
Renewable Energy Coach an...
Senior Engineer
THE EXPERTS MEP SOLUTIONS
Mechanical Engineering Pr...
Mechanical Design Enginee...